FM-CM-230 Conductivity Monitor
Features:
  • On-line panel mount conductivity monitor
  • Display in S and mS
  • Simulate Function, Non-isolated 4-20mA current output
  • Automatic temperature compensation
Technical Parameter:
Sensor input range: 0~20, 0~200, 0~2000S/cm
0~20mS/cm
Accuracy: 1.5% (FS)
Stability: 2 10 3 (FS) / 24h
Display: Back light 3.5-bit LCD
Temperature comp: Automatic thermistor temp compensation, standard temperature: 25
Electrode: 1.0cm1 plastic platinum gold electrode1/2 thread
Cable length: 5m or others(5~30m)
Current output: Non-isolated 4-20mA current output
Power supply: AC 220V 10% 50Hz
Environmental conditions: Temperature: 0~50棻Humidity: 85%RH
Dimensions: 48 96 100mm (height width depth)
Panel cut-out 45X91mm
nstallation Cut-out Fit-In
Application:
  • RO/DI system monitor
  • Cooling water monitor
  • Industrial water process monitor
  • Desalinization monitor
  • Water quality monitor



































































































FM-TDS-230 Conductivity Monitor
Features:
  • On-line panel mount conductivity monitor
  • Display in S and mS
  • Simulate Function, Non-isolated 4-20mA current output
  • Automatic temperature compensation
Technical Parameter:
Sensor input range: 0~20, 0~200, 0~2000 ppm
Accuracy: 1.5% (FS)
Stability: 2 10 3 (FS) / 24h
Display: Back light 3.5-bit LCD
Temperature comp: Automatic thermistor temp compensation, standard temperature: 25
Electrode: 1.0 cm1 plastic platinum gold electrode1/2 thread
Cable length: 5m or others(5~30m)
Current output: Non-isolated 4-20mA current output
Power supply: AC 220V 10% 50Hz
Environmental conditions: Temperature: 0~50棻Humidity: 85%RH
Dimensions: 48 96 100mm (height width depth)
Panel cut-out 45X91mm
Installation Cut-out Fit-In
Application:
  • RO/DI system monitor
  • Cooling water monitor
  • Industrial water process monitor
  • Desalinization monitor
  • Water quality monitor
FM-EC-450 Conductivity Controller
Features:
  • On-line panel mount conductivity controller
  • Display in S , ppm and mS
  • Simulate Function, Isolated 4-20mA current output
  • Relay control output. Hi, On, Off.
  • Automatic programmable temperature compensation
  • Display and/or Control: S, mS, ppm or
Technical Parameter:
Sensor input range: 0~20, 0~200, 0~2000S/cm
0~20, 0~200, 0~2000ppm
0~20mS/cm
Accuracy: 1.5% (FS)
Stability: 2 10 3 (FS) / 24h
Display: Back light 3.5-bit LCD
Temperature comp: Automatic programmable compensation standard Temperature: 25
Electrode: 1.0cm1 plastic platinum gold electrode1/2 thread
Cable length: 5m or others(5~30m)
Current output: Isolated 4-20mA current output
Control output: Relay output, Hi, on, off
Power supply: AC 220V 10% 50Hz
Environmental conditions: Temperature: 0~50棻Humidity: 85%RH
Dimensions: 48 96 100mm (height width depth)
Panel cut-out 45X91mm
Installation: Cut-out Fit-In
Application:
  • RO/DI system control
  • Cooling water control
  • Industrial water process control
  • Desalinization monitor
  • Water quality monitor
FM-CM-5230 Conductivity Monitor
Features:
  • On-line panel mount conductivity monitor
  • Display in S , ppm and mS
  • Simulate Function, Isolated 4-20mA current output
  • Automatic programmable temperature compensation
  • Display and/or Control: S, mS, ppm or
Technical Parameter:
Sensor input range: 0~20, 0~200, 0~2000S/cm
0~20, 0~200, 0~2000ppm
0~20mS/cm
Accuracy: 1.5% (FS)
Stability: 2 10 3 (FS) / 24h
Display: Back light 3.5-bit LCD
Temperature comp: Automatic programmable compensation standard Temperature: 25
Electrode: 1.0cm1 plastic platinum gold electrode1/2 thread
Cable length: 5m or others(5~30m)
Current output: Isolated 4-20mA current output
Power supply: AC 220V 10% 50Hz
Environmental conditions: Temperature: 0~50棻Humidity: 85%RH
Dimensions: 96 96 130mm (height width depth)
Panel cut-out: 92X92mm
Installation: Cut-out Fit-In
Application:
  • RO/DI system monitor
  • Cooling water monitor
  • Industrial water Process monitor
  • Desalinization monitor
  • Water quality monitor
FM-CM-5630 Conductivity Controller
Features:
  • On-line panel mount conductivity controller
  • Display in S , ppm and mS
  • Simulate Function, Isolated 4-20mA current output
  • Relay control output. Hi, Lo, On, Off
  • Automatic programmable temperature compensation
  • Display and/or Control: S, mS, ppm or
Technical Parameter:
Sensor input range: 0~20, 0~200, 0~2000S/cm
0~20, 0~200, 0~2000ppm
0~20mS/cm
Accuracy: 1.5% (FS)
Stability: 2 10 3 (FS) / 24h
Display: Back light 3.5-bit LCD
Temperature comp: Automatic programmable compensation standard Temperature: 25
Electrode: 1.0cm1 plastic platinum gold electrode1/2 thread
Cable length: 5m or others(5~30m)
Current output: Isolated 4-20mA current output
Control output: Relay output, Hi, Lo, on, off
Power supply: AC 220V 10% 50Hz
Environmental conditions: Temperature: 0~50棻Humidity: 85%RH
Dimensions: 96 96 130mm (height width depth)
Panel cut-out: 92X92mm
Installation Cut-out Fit-In
Application:
  • RO/DI system control
  • Cooling water control
  • Industrial water process control
  • Desalinization monitor
  • Water quality monitor