CDLF Light vertical multistage centrifugal pump |
CDL/CDLF is a kind of vertical non-self priming multistage centrifugal pump, which is driven by a standard electric motor. The motor output shaft directly connects with the pump shaft through a coupling. The pressure-resistant cylinder and flow passage components are fixed between pump head and in-and outlet section with tie-bar bolts. The inlet and outlet are located at the pump bottom at the same plane. This kind of pump can be equipped with an intelligent protector to effectively prevent it from dry-running, out-of-phase and overload |
|
Operation conditions |
- Thin, clean, non-flammable and non-explosive liquid containing no solid granules and fibers.
- Liquid temperature:
- Normal temperature type:-15¡æ~+70¡æ,
- Hot water type:+70¡æ~+120¡æ
- Ambient temperature :up to +40¡æ
- Altitude :up to 1000m
|
Feed Water Pump |
50 Hz |
60 Hz |
Q*H |
Connection |
Voltage |
RO SYSTEM |
CDLF 4-4 / 0.75 KW |
CDLF 4-3 / 1.1 KW |
2.0 t/h * 35m |
Flanged |
220V/380V/3Phase |
6000 GPD |
CDLF 4-4 / 0.75 KW |
CDLF 4-3 / 1.1 KW |
2.5 t/h * 32m |
Flanged |
220V/380V/3Phase |
9000 GPD |
CDLF 4-4 / 0.75 KW |
CDLF 4-3 / 1.1 KW |
3.5 t/h * 30m |
Flanged |
220V/380V/3Phase |
12000 GPD |
CDLF 8-4 / 1.5 KW |
CDLF 4-4 / 1.5 KW |
5.5 t/h * 40m |
Flanged |
220V/380V/3Phase |
18000 GPD |
CDLF 8-4 / 1.5 KW |
CDLF 8-3 / 2.2 KW |
7.0 t/h * 38m |
Flanged |
220V/380V/3Phase |
24000 GPD |
CDLF 16-3 / 3 KW |
CDLF 8-3 / 2.2 KW |
10.0 t/h * 40m |
Flanged |
220V/380V/3Phase |
36000 GPD |
CDLF 16-3 / 3 KW |
CDLF 16-2 / 4 KW |
12.0 t/h * 38m |
Flanged |
220V/380V/3Phase |
48000 GPD |
CDLF 16-3 / 3 KW |
CDLF 16-2 / 4 KW |
15.0 t/h * 34m |
Flanged |
220V/380V/3Phase |
60000 GPD |
CDLF 20-3 / 3 KW |
CDLF 20-2 / 4 KW |
18.0 t/h * 37m |
Flanged |
220V/380V/3Phase |
72000 GPD |
CDLF 20-3 / 3 KW |
CDLF 20-2 / 4 KW |
22.0 t/h * 33m |
Flanged |
220V/380V/3Phase |
90000 GPD |
CDLF 32-30-2 / 5.5 KW |
CDLF 32-20-2 / 5.5 KW |
28.0 t/h * 38m |
Flanged |
220V/380V/3Phase |
120000 GPD |
|
Note: Other models per request |
High Pressure Pump |
50 Hz |
60 Hz |
Q*H |
Connection |
Voltage |
RO SYSTEM |
CDLF 2-11 / 1.1 KW |
CDLF 2-7 / 1.1 KW |
0.8 t/h * 100m |
Flanged |
220V/380V/3Phase |
800 GPD |
CDLF 2-13 / 1.5 KW |
CDLF 2-9 / 2.2 KW |
1.0 t/h * 110m |
Flanged |
220V/380V/3Phase |
1500 GPD |
CDLF 2-15 / 1.5 KW |
CDLF 2-11 / 2.2 KW |
1.2 t/h * 110m |
Flanged |
220V/380V/3Phase |
3000 GPD |
CDLF 2-15 / 1.5 KW |
CDLF 2-11 / 2.2 KW |
2.0 t/h * 110m |
Flanged |
220V/380V/3Phase |
6000 GPD |
CDLF 4-14 / 3.0 KW |
CDLF 4-10 / 4.0 KW |
2.5 t/h * 120m |
Flanged |
220V/380V/3Phase |
9000 GPD |
CDLF 4-16 / 3.0 KW |
CDLF 4-10 / 4.0 KW |
3.5 t/h * 120m |
Flanged |
220V/380V/3Phase |
12000 GPD |
CDLF 8-12 / 4.0 KW |
CDLF 4-12 / 4.0 KW |
5.5 t/h * 120m |
Flanged |
220V/380V/3Phase |
18000 GPD |
CDLF 8-14 / 5.5 KW |
CDLF 8-8 / 5.5 KW |
7.0 t/h * 120m |
Flanged |
220V/380V/3Phase |
24000 GPD |
CDLF 8-16 / 5.5 KW |
CDLF 8-10 / 7.5 KW |
10.0 t/h * 120m |
Flanged |
220V/380V/3Phase |
36000 GPD |
CDLF 16-10 / 11 KW |
CDLF 16-6 / 11 KW |
12.0 t/h * 120m |
Flanged |
220V/380V/3Phase |
48000 GPD |
CDLF 16-10 / 11 KW |
CDLF 16-7 / 15 KW |
15.0 t/h * 120m |
Flanged |
220V/380V/3Phase |
60000 GPD |
CDLF 20-10 / 11 KW |
CDLF 20-7 / 15 KW |
18.0 t/h * 120m |
Flanged |
220V/380V/3Phase |
72000 GPD |
CDLF 20-12 / 15 KW |
CDLF 20-7 / 15 KW |
22.0 t/h * 120m |
Flanged |
220V/380V/3Phase |
90000 GPD |
CDLF 32-80 / 15 KW |
CDLF 20-8 / 15 KW |
28.0 t/h * 120m |
Flanged |
220V/380V/3Phase |
120000 GPD |
|
Note: Other models per request |
CHL Light horizontal multistage centrifugal pump |
Horizontal multistage non-self-priming centrifugal pump, attached with long shaft electric motor. Compact structure renders small size of pump; axial inlet and radial outlet. |
Operation condition |
|
- Liquid temperature:
- Normal temperature type: -15¡æ~+70¡æ
- Hot water type: +70¡æ~+110¡æ
- Highest ambient temperature: +40¡æ
- Max. operation pressure :10 bar
- Max. inlet pressure is limited by max. operation pressure
|
50 Hz |
60 Hz |
Q*H |
Connection |
Voltage |
RO SYSTEM |
CHLF2-40/0.55KW |
CHLF2-30/0.75KW |
0.8 t/h * 32m |
Threaded |
220V/380V/3Phase |
800 GPD |
CHLF2-40/0.55KW |
CHLF2-30/0.75KW |
1.0 t/h * 32m |
Threaded |
220V/380V/3Phase |
1500 GPD |
CHLF2-40/0.55KW |
CHLF2-30/0.75KW |
1.2 t/h * 30m |
Threaded |
220V/380V/3Phase |
3000 GPD |
|
Note: Other models per request |
|
TD In-line circulation pump |
The TD series pumps are single stage in-line centrifugal pumps, equipped with standard motor and mechanical seal. Comparing with other pumps in similar structure, these pumps are less accessible to the impurity in the liquid |
NPSH |
To avoid the cavitations, and lessen the libration and noise, you are suggested to adopt NPSH, to make sure that the pumps are under optimal operation condition. The data in the sheet are relative pressure(Bar),which can be read on manometer at the inlet side of the pumps. |
SJ Stainless steel multistage deep-well submersible pump |
This series is applicable to circulation and pressurizing of the clean water and softened water;
This series is made from stainless steel 304 and has good corrosive resistance for conveying cold water containing small amount of oxides. It is also used for conveying slightly alkaline water and de-mineralized water. Pump made from stainless steel 316 and FPM is applicable to conveying highly corrosive liquid |
Working conditions |
- Solid grain-or-fiber-free dilute clean non-corrosive liquids;
- Maximum liquid temperature:35¡æ
- Maximum working pressure:30 bar
- PH:6.5~8.5
- Maximum diving depth:<=50m
|